Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Referenties

Fotovoltaïsche warmte in twee varianten voor warm water en verwarming

Een netgekoppeld en een autonoom PV-systeem produceren in het Zwarte Woud warm water en ondersteunen de verwarming.

Lees meer...
reduxi Logo

Partner

Reduxi nu compatibel met my-PV

Slimme warmwaterproductie met PV-overschot: Reduxi is nu volledig compatibel met my-PV apparaten.

Lees meer...
Five white my-PV company cars in front of the building with wooden facade, logo, and solar panels.

Bedrijf

Elektrische auto’s bij my-PV

We zien de toekomst niet alleen in (zonne-)elektrische gebouwentechnologie, maar ook op het gebied van mobiliteit.

Lees meer...