Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Referenties

Energietransitie bij de wijngaard: zonnepanelen in plaats van gas in Zuid-Tirol

Wijngaard gebruikt overtollige zonne-energie: my-PV zorgt voor efficiënte warmwaterproductie in Zuid-Tirol.

Lees meer...
A row of suburban houses with solar panels on the roofs, a garden area, and a gazebo in the backyard under a clear blue sky.

Referenties

Schoolproject brengt zonne-energie voor verwarming naar een rijtjeshuis.

Warm water van een off-grid zonne-energiesysteem in plaats van een olieketel – een betaalbaar alternatief.

Lees meer...
Logo of the brand FENECON

Partner

New Compatibility Partner: FENECON

The solar-electric solutions from my-PV are now also compatible with products from FENECON.

Lees meer...