Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Referenze

Transizione energetica nella cantina: fotovoltaico invece del gas in Alto Adige

La cantina usa l’eccesso di energia fotovoltaica: my-PV assicura acqua calda efficiente in Alto Adige.

Leggi di più...
A row of suburban houses with solar panels on the roofs, a garden area, and a gazebo in the backyard under a clear blue sky.

Referenze

Progetto scolastico porta il riscaldamento solare in una casa a schiera

Acqua calda da una soluzione fotovoltaica off-grid invece di un impianto a gasolio – un'alternativa conveniente.

Leggi di più...
Logo of the brand FENECON

Partner

New Compatibility Partner: FENECON

The solar-electric solutions from my-PV are now also compatible with products from FENECON.

Leggi di più...