Support AC•THOR / AC•THOR s Firmware a Changes
Support: AC•THOR / AC•THOR 9s Firmware a0020410 changes
- All signal sources, including those that were previously only selectable via the web interface, can now be set on the display.
- The frequency mode is no longer a separate operating mode. Instead, frequency control can be selected as a signal source. Thus, the operating modes M1 to M7 can now be used in AC off-grid systems.
- A firmware update on a unit in "M8 frequency mode" automatically switches it to "M1 hot water" operating mode and "frequency" is set as the signal source.
- New signal source "Fronius Gen24 Manual" added.
- Correction for operating mode M7. The PWM output signal works correctly again.
- The heat pump operating mode M4 can now also be used if no meter value is known at the feed-in point. The power specifications, e.g. via Modbus TCP, are sufficient information for the control.
- The combination with charging columns from KEBA and Eaton is now also possible if no meter value is known at the feed-in point. The power specifications, e.g. via Modbus TCP, are sufficient as information for the control.
- Further information here:/(German)
- Optimising the data connection with my-PV.LIVE
- Here you will find the latest
More articles
L'entreprise
Nouveaux prix pour les produits my-PV en vigueur à partir du 1er juillet 2026En raison de la hausse des coûts de personnel, matériaux et production, un ajustement des prix est nécessaire.
lire la suite...Généralités
my-PV à Intersolar 2026Du 23 au 25 juin 2026, Intersolar Europe à Munich rouvrira ses portes – et my-PV sera également présent.
lire la suite...Références
Maître électricien allemand avec un bâtiment d'entreprise alimenté par l'énergie solaireUne entreprise de solaire de Basse-Franconie chauffe son bâtiment commercial à l'aide d'électricité PV régulée en continu.
lire la suite...