Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Partenaires

Nouveau partenaire de compatibilité : smart-me

Nous sommes heureux d'annoncer que les produits de my-PV sont désormais compatibles avec les solutions smart-me.

lire la suite...
Flowchart guiding photovoltaic system choice, showing options for using electricity for household power, water heating, or both, with product recommendations.

Généralités

How do I find the right my-PV product?

Do you have a rooftop photovoltaic system with enough surplus energy? Then it’s time to consider a my-PV product.

lire la suite...
A modern two-story house with a green and white van parked in the driveway, surrounded by greenery and a brick wall, under a partly cloudy sky.

Références

La maison familiale belge compte sur l'AC•THOR

Famille belge augmente l'autoconsommation photovoltaïque à 74% avec AC•THOR, le tout sans stockage de batterie.

lire la suite...