Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Logo of "homewizard" with a green and blue gradient lightning bolt symbol on the left.

Partner

AC ELWA 2 and AC•THOR series now compatible with HomeWizard

The HomeWizard P1 Meter is now fully compatible with the AC ELWA 2 and AC•THOR series!

Read more...
Modern house with large glass doors, a wooden deck, and a patio umbrella, surrounded by greenery under a clear blue sky.

References

68% solar fraction in the annual energy balance of the Singen Microhouse

A study by HTWG Konstanz shows the solar fraction achieved by a solar-electric heating system in practice.

Read more...

References

Dairy company opts for off-grid heat supply using PV energy

A commercial building in Regensburg took advantage of a roof renovation to install a photovoltaic system.

Read more...