)
AC•THOR 9s – Operation with 3 single-phase heating elements
Our "Support" section offers many practical tips that will help you with the installation and commissioning of our devices.
The load control of 3 single-phase heating elements is a special form of operating mode M1 for hot water.
CAUTION:
This is to be clearly distinguished from operating mode M2 "Layer Charging," where load control is switched to another 3-phase consumer using an external opener and a closer!
The following instructions from the operating manual are important:
)
Solution
The regular operation for 3 single-phase heating elements can be set with a single adjustment. Simply switch the "Load Priority" accordingly under "Settings" (gear symbol).
Good to know
Tip: Connect the topmost heating element to the control output OUT-3 of the AC•THOR 9s. If you accidentally did not follow the order, simply switch the consumption plugs. This saves rewiring!
More articles
)
References
Heat generation from PV surplus in the Lavant ValleyNestled in the picturesque Lavant Valley, a renovated multi-family home demonstrates the full potential of solar power.
Read more...)
Support
How long does it take to heat up the thermal store?Have you ever wondered how long it takes to heat up the heat storage tank?
Read more...)
Company
2 Million Views: Milestone for the my-PV YouTube ChannelWe’ve reached a significant milestone: 2 million views on our channel!
Read more...